BS 7883 is the British Standard for the design, installation, inspection and maintenance of anchor systems used for personal fall protection. It covers the equipment your personnel rely on when Working at Height – from Fall Arrest Eyebolts and Safety Line Systems to rigid rail systems and Mobile Man Anchors.
Heightsafe’s Compliance Testing team inspects and tests anchor systems to BS 7883:2019 for commercial, industrial and public sector buildings throughout the UK. We don’t just tell you whether a system passes or fails.
We explain what the result means, what needs to happen next and how to keep your building compliant for the life of the system – with a clear route to full compliance, even if your System Technical File is missing.
Documentation is now as important as the hardware
The 2019 revision of BS 7883 replaced the 2005 version and raised the bar on documentation. Under the current standard, a system that is physically sound is no longer the whole picture – duty holders are also expected to hold a complete record of how the system was designed and installed.
The standard formalises the role of the System Designer, who is responsible for producing a System Technical File and passing it to the duty holder to keep for the service life of the system. The file should be available to anyone carrying out future inspection or maintenance.
Why hidden elements matter: if an inspector cannot see how an anchor is fixed to the structure, the technical file is the evidence that it was installed correctly.
And it doesn’t mean your system has failed
Many anchor systems in use today were installed before BS 7883:2019, or have changed hands between contractors and building owners over the years. As a result, the technical documentation is often incomplete or missing altogether.
The current standard recognises this. Rather than the simple pass or fail of the previous edition, BS 7883:2019 allows inspectors to record a more accurate result for systems that are safe to use but don’t yet meet every requirement of the standard.
Where your system is mechanically sound and presents no immediate safety concern, but the System Technical File is missing or incomplete, we can issue a Conditional Pass. Your system can remain in use, and you’ll receive a clear report setting out exactly what is needed to bring it into full compliance.
Understanding your inspection result
Pass
The system meets the requirements of BS 7883:2019, including documentation.
No technical file?
Conditional Pass
The system is safe to use, but does not meet every requirement of the standard (for example, the System Technical File is missing). Recommendations are provided to achieve full compliance.
Conditional Fail
An immediate safety concern has been identified. The system should not be used until remedial work is completed.
Fail
The system is not safe and should be taken out of service.
A Conditional Pass is a starting point, not an end point. Once your system has been tested, our specialists will recommend the most practical and cost-effective way forward. In most cases, this will be one of two routes.
Where your existing system is in good condition and suitable for continued use, we can compile a retrospective System Technical File.
This may involve surveying the system layout, confirming the product and manufacturer, producing drawings and calculations, and carrying out reverse engineering checks on hidden elements – which can mean opening up the roof build-up to confirm how anchors are fixed to the structure. The findings are recorded and photographed so your file is complete and ready for every future inspection.
Best suited to: sound, well-designed systems that are simply missing their paperwork.
Where an existing system is no longer suitable – because of its condition, age, design or a change in how the roof is used – producing a technical file may not be the best use of your budget. In these cases, we can design and install a new Fall Protection system to replace it.
Every new Heightsafe system is supplied with complete documentation from day one, including the System Technical File, Examination Scheme and O&M Manual.
Best suited to: systems that are coming to the end of their service life, no longer meet the needs of the building, or would be uneconomical to document.
Our team will always explain the options honestly. If a retrospective file is the right answer, we’ll recommend it. If a new system is necessary, we’ll tell you why.
We work with you to make sure your anchor systems are compliant now, and stay that way.
Short term
Safe to use today
We inspect and test your system, confirm whether it is safe for use and issue the appropriate result. Where a Conditional Pass is given, your personnel can continue to work safely while next steps are agreed.
Medium term
A clear, budgeted plan
We recommend the right route to full compliance – a retrospective System Technical File or a new installation – and help you plan and prioritise the work around your budget and maintenance programme. For clients with multiple sites, we can coordinate a programme across your entire portfolio.
Long term
Compliant for the life of the system
With a complete System Technical File in place, we provide ongoing inspection, testing and maintenance in line with your Examination Scheme. Reports and certificates are kept accessible through our Prime Portal, so your records are always up to date and ready for audit.
Complete Lifecycle Support
Surveying, design, installation, testing, maintenance and training from one specialist – so the team testing your system can also put right anything that needs attention.
Experienced Specialists
Our designers, surveyors, engineers and inspectors understand both the technical requirements of BS 7883 and the practical realities of busy commercial roofs.
Honest, Practical Advice
We give clear recommendations and never push a new system where a retrospective technical file will do the job.
Nationwide Coverage
With offices across England, Scotland and Wales, we support single sites and multi-site portfolios throughout the UK.
Clear Documentation
Easy-to-understand reports, certification and technical files make it simpler to plan remedial work and demonstrate compliance.
BS 7883 is the British Standard covering the design, selection, installation, use, maintenance and inspection of anchor systems used for personal fall protection. The current version is BS 7883:2019.
A System Technical File is a record of how an anchor system was designed and installed. It typically includes layout drawings, design calculations, structural fixing details, as-built drawings and evidence of hidden elements. It should be held by the duty holder for the life of the system.
Not necessarily. A missing technical file does not mean the system is unsafe. If our inspection finds the system is safe to use, we can issue a Conditional Pass and recommend how to achieve full compliance.
A Conditional Pass means the system is safe to use and presents no immediate concern, but does not meet every requirement of BS 7883:2019. Your report will set out the steps needed to reach full compliance.
Yes. We can produce a retrospective System Technical File for existing systems, including those installed by other contractors. This may involve reverse engineering checks to confirm how hidden elements are fixed.
Not always. If your system is in good condition and suitable for its intended use, a retrospective technical file is usually the most cost-effective option. We’ll only recommend a new system where it is genuinely necessary.
Inspection frequency depends on the system type, how often it is used, the environment and the manufacturer’s instructions. Many permanent systems are inspected at least annually, while some may need more frequent checks.
We also provide dedicated Safety Line Testing, Eye Bolt and Abseil Point Testing and Mobile Man Anchor Testing.
Not sure whether your fall protection system meets BS 7883:2019? Get in touch with Heightsafe’s friendly, professional team today for free, no obligation advice.
Simply complete the below and one of our experts will be in touch.